| Load level | % of rated capacity | % of total cycles |
|---|---|---|
| Load 1 (heaviest) | ||
| Load 2 | ||
| Load 3 | ||
| Load 4 | ||
| Load 5 (lightest) |
The working class of a crane is determined by two independent factors defined in ISO 4301-1:2016 and GB/T 3811: how often the crane works (utilization class U) and how heavily it is loaded (load state Q). The calculator combines both to give the working class A.
A work cycle starts when you begin lifting a load and ends when you are ready to lift the next one. The total number of cycles over the crane's design life determines the utilization class:
The load spectrum factor Kp measures how heavily loaded your cycles are. Each load level contributes with the cube of its ratio to rated capacity — this reflects how fatigue damage scales with load:
The U class and Q state cross-reference in the working class matrix (see the Matrix tab) to give A1–A8. A higher Q state reaches a given A class at a lower utilization — a heavily loaded crane fatigues faster than a busy but lightly loaded one.
The example from FEM 9.511: a crane with medium load spectrum, hoisting speed 5 m/min, average hook travel 3 m, 5 cycles per hour, two-shift operation (16 h/day) gives an equivalent daily operating time of 1.6 h — duty class M5 (GB A5, FEM 2m).
| Utilization class | Max total work cycles N | Service description |
|---|---|---|
| U0 | 1.6 × 10⁴ | Infrequent use |
| U1 | 3.2 × 10⁴ | |
| U2 | 6.3 × 10⁴ | |
| U3 | 1.25 × 10⁵ | Occasional use |
| U4 | 2.5 × 10⁵ | Regular light use |
| U5 | 5 × 10⁵ | Regular intermittent use |
| U6 | 1 × 10⁶ | Regular busy use |
| U7 | 2 × 10⁶ | Intensive use |
| U8 | 4 × 10⁶ | |
| U9 | > 4 × 10⁶ |
| Load state | Nominal spectrum factor Kp | Description |
|---|---|---|
| Q1 — light | 0.125 | Rarely lifts rated load; normally light loads |
| Q2 — medium | 0.25 | Sometimes lifts rated load; normally moderate loads |
| Q3 — heavy | 0.5 | Frequently lifts rated load; normally heavy loads |
| Q4 — very heavy | 1.0 | Regularly lifts at or near rated load |
| Load state ↓ / Utilization → | U0 | U1 | U2 | U3 | U4 | U5 | U6 | U7 | U8 | U9 |
|---|---|---|---|---|---|---|---|---|---|---|
| Q1 (Kp ≤ 0.125) | A1 | A1 | A1 | A2 | A3 | A4 | A5 | A6 | A7 | A8 |
| Q2 (Kp ≤ 0.25) | A1 | A1 | A2 | A3 | A4 | A5 | A6 | A7 | A8 | A8 |
| Q3 (Kp ≤ 0.5) | A1 | A2 | A3 | A4 | A5 | A6 | A7 | A8 | A8 | A8 |
| Q4 (Kp ≤ 1.0) | A2 | A3 | A4 | A5 | A6 | A7 | A8 | A8 | A8 | A8 |
Cells are clamped to the A1–A8 range per ISO 4301-1:2016 — classes above A8 are collectively rated A8.
| Standard | Duty code equivalence | |||||
|---|---|---|---|---|---|---|
| ISO / BS / DIN | M3 | M4 | M5 | M6 | M7 | M8 |
| GB (China) | A3 | A4 | A5 | A6 | A7 | A8 |
| FEM | 1Bm | 1Am | 2m | 3m | 4m | 5m |
| CMAA (US) | A | B | C | D | E | F |
| HMI | H2 | H3 | H4 | H5 | H5 | H6 |
| Safe working period SWP (h) | 400 | 800 | 1,600 | 3,200 | 6,300 | 12,500 |
| Duty cycle %ED | 25 | 30 | 40 | 50 | 60 | 60 |
| Starts per hour | 150 | 180 | 240 | 300 | 360 | 360 |