Design load P = working load × dynamic factor. All checks use the allowable stress method with your material [σ]:
Most lug failures trace to two mistakes: hole too close to the edge (check 2 fails first) and welds sized by eye (check 5). If any check exceeds 100%, increase thickness, edge distance or weld leg — the utilization bars show which fix pays off fastest.
This tool covers in-plane loading on a single plate lug. Side pulls, cheek plates, tapered lugs and fatigue loading need a full engineering check.